Please use this identifier to cite or link to this item:
https://ric.cps.sp.gov.br/handle/123456789/43345| Title: | Sensor de posicionamento com contador de tempo para troca de decúbito. |
| Other Titles: | Positioning sensor with timer for changing decubitus position. |
| Authors: | OLIVEIRA, Guilherme Leonço |
| Advisor: | BATISTON, Michele Cristina OLIVEIRA, José Rodrigo de |
| Other contributor: | BATISTON, Michele Cristina |
| type of document: | Artigo Científico |
| Keywords: | Sensor;Pacientes |
| Issue Date: | 11-Dec-2025 |
| Publisher: | 196 |
| Citation: | OLIVEIRA, Guilherme Leonço. Sensor de posicionamento com contador de tempo para troca de decúbito. Trabalho de conclusão de curso (Curso Superior de Tecnologia em Sistemas Biomédicos) - Faculdade de Tecnologia FATEC Bauru, Bauru, 2025. |
| Abstract: | A elevada incidência de úlceras por pressão em pacientes acamados está diretamente
ligada à dificuldade de gerenciar a mudança de decúbito de forma regular e eficaz,
uma tarefa frequentemente comprometida pela rotina intensa das equipes de saúde.
Diante dessa problemática, o presente estudo focou no desenvolvimento de um
dispositivo de auxílio, materializado em um protótipo de cinta com sensores de força
resistivos. A operação do sistema é gerenciada pela plataforma de prototipagem
Arduino Uno, programada para alertar a equipe assistencial via alarme sonoro e visual
ao término de um ciclo de duas horas. Crucialmente, o sistema só reinicia o novo
monitoramento do ciclo após verificar, por meio dos sensores de força, uma nova
efetiva redistribuição da pressão corporal, garantindo que o reposicionamento foi bem
sucedido. O protótipo funcional resultante preenche uma lacuna tecnológica, visto que
as soluções atuais de mercado se limitam a temporizadores desse ciclo, sem validar
a qualidade do procedimento. Dessa forma, a solução proposta revela-se uma
ferramenta de grande potencial para otimizar o cuidado preventivo, auxiliando as
equipes de saúde a mitigar a ocorrência de lesões por pressão. The high incidence of pressure ulcers in bedridden patients is directly associated with the difficulty of managing regular and effective repositioning, a task often compromised by the demanding routine of healthcare teams. In response to this issue, the present study focused on developing an assistive device, materialized as a prototype belt equipped with force-sensitive resistive sensors. The system’s operation is managed by an Arduino Uno prototyping platform, programmed to alert the healthcare team through audible and visual alarms at the end of each two-hour cycle. Crucially, the system only restarts a new monitoring cycle after verifying, through the force sensors, that a new and effective redistribution of body pressure has occurred, ensuring that the repositioning was successfully completed. The resulting functional prototype fills a technological gap, since current market solutions are limited to simple cycle timers and do not validate the quality of the procedure. Thus, the proposed solution presents itself as a tool with great potential to optimize preventive care by assisting healthcare teams in reducing the occurrence of pressure injuries. |
| URI: | https://ric.cps.sp.gov.br/handle/123456789/43345 |
| Appears in Collections: | Trabalhos de Conclusão de Curso |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| TA_GUILHERME LEONÇO.pdf Restricted Access | 403.33 kB | Adobe PDF | View/Open Request a copy | |
| TG_GUILHERME LEONÇO.pdf | 1.03 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.