Please use this identifier to cite or link to this item: https://ric.cps.sp.gov.br/handle/123456789/12104
Title: Capacidade do protótipo de amostrador de ar portátil impactar micro-organismos: testes microbiológicos
Other Titles: Capacity of the portable air sampler prototype to impact microorganisms: microbiological tests
Authors: MAZZETTO, Solange Aparecida Monge dos Reis
Advisor: ALMEIDA, Rogéria Maria Alves de
type of document: Artigo científico
Keywords: Oxigênio;Contaminação;Contaminação ambiental;Alergia e imunologia;Desinfecção da água;Traqueia;Fungos;Microrganismos fitopatogênicos;Administração hospitalar;Serviços hospitalares
Issue Date: Jul-2015
Publisher: 196
Citation: MAZZETTO, Solange Aparecida Monge dos Reis. Capacidade do protótipo de amostrador de ar portátil impactar micro-organismos: testes microbiológicos. Trabalho de conclusão de curso (Curso Superior de Tecnologia em Sistemas Biomédicos) - Faculdade de Tecnologia FATEC Bauru, Bauru, 2015.
Abstract: A busca por um ambiente com baixo índice de contaminação tem motivado o uso de amostradores de ar para a coleta, análise e identificação de micro-organismos patogênicos presentes na atmosfera e, principalmente, em ambientes hospitalares, onde estão relacionados à saúde de pacientes, levando ao aparecimento de alergias e infecções. A presente pesquisa tem como objetivo testar o desempenho de um amostrador de ar que possui em seu interior uma placa micro controladora por hardware Arduino, programada para coletar 28 l/minuto de ar durante dez minutos. De acordo com os testes microbiológicos observou-se que o mais viável foi à coleta do ar por uma bomba de sucção e transportado até um erlenmeyer de 50,26 cm2 de fundo contendo 27 ml de Agar Dextrose- Sabouraud, através de uma traqueia infantil . O meio de cultura foi incubado a 250 C para isolamento de bolores (3 a 5 dias ). Os gêneros mais frequentes foram Mycelia esterilia, Cladosporium sp, Candida albicans e Rhodotorulla rubra, isolados de 5 pontos do laboratório de análises de equipamentos médico hospitalares da Faculdade de Tecnologia de Bauru (FATEC). Concluiu-se que o modelo utilizado nas coletas promoveu rapidez, e proporcionou resultados em medidas confiáveis por ser um equipamento que permite calibração em seu sistema de captação de ar, além de ser de fácil operação e baixo custo comparado ao semelhante oferecido pelo mercado.
The search for an environment with low infection rate has motivated the use of air samplers for the collection, analysis and identification of pathogenic micro-organisms present in the atmosphere, and especially in hospital settings, where they are related to the health of patients, leading the onset of allergies and infections. This research aims to test the performance of an air sampler that has in its interior a micro controller board for Arduino hardware, scheduled to collect 28 liters / minute of air for ten minutes. According to microbiological tests it was observed that the most viable was the collection of the air by a suction pump and transported to a conical flask containing 50.26 cm2 bottom 27 ml of Sabouraud Agar Dextrose- through an infant trachea. The culture medium was incubated at 250C for isolation of molds (3 to 5 days). The most common genera were Mycelia esterilia, Cladosporium sp, Candida albicans and Rhodotorula rubra, isolated of 5 laboratory points of hospital medical equipment analyzes of Bauru School of Technology (FATEC). It was concluded that the model used in the collection promoted quickly, and provided results in reliable measurements to be a device that allows calibration in its air inlet system as well as being easy to operate and low cost compared to similar offered by the market.
La búsqueda de un ambiente con baja tasa de infección ha motivado el uso de muestreadores de aire para la recopilación, análisis e identificación de microorganismos patógenos presentes en la atmósfera, y sobre todo en el ámbito hospitalario, en el que se relacionan con la salud de los pacientes, lo que lleva la aparición de alergias e infecciones. Esta investigación tiene como objetivo poner a prueba el rendimiento de un muestreador de aire que tiene en su interior una placa de micro controlador para el hardware Arduino, programada para recoger 28 litros / minuto de aire durante diez minutos. De acuerdo con las pruebas microbiológicas se observó que la más viable era la colección del aire por una bomba de succión y se transporta a un matraz cónico que contiene 50,26 cm2 parte inferior 27 ml de Agar Sabouraud Dextrose- a través de una tráquea infantil. El medio de cultivo se incubó a 250C para el aislamiento de moldes (de 3 a 5 días). Los géneros más comunes fueron esterilia micelios, Cladospoirum sp, Candida albicans y Rhodotorula rubra, aisladas de 5 puntos de laboratorio de equipos médicos de hospital análisis de la Escuela de Tecnología de Bauru (FATEC). Se concluyó que el modelo utilizado en la colección promovido rápidamente, y proporcionó los resultados en mediciones fiables para ser un dispositivo que permite la calibración en su sistema de entrada de aire, así como ser fácil de manejar y de bajo costo en comparación con similares ofrecido por el mercado.
URI: https://ric.cps.sp.gov.br/handle/123456789/12104
Appears in Collections:Trabalhos de Conclusão de Curso

Files in This Item:
File Description SizeFormat 
sistemasbiomedicos_2015_1_solangemazzetto_capacidadedoprototipodeamostrador.pdf
  Restricted Access
1.05 MBAdobe PDFView/Open Request a copy


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.