Please use this identifier to cite or link to this item: https://ric.cps.sp.gov.br/handle/123456789/49473
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorFERREIRA, André Rosa-
dc.contributor.advisorFREITAS, Carlos Alberto de-
dc.contributor.authorKAVAI, Claudio Kazuo-
dc.contributor.authorLOPES, Gilson Silva-
dc.contributor.authorSILVA, Santiago de Moraes-
dc.contributor.otherFERREIRA, André Rosa-
dc.contributor.otherFREITAS, Carlos Alberto de-
dc.contributor.otherFREITAS, Marcos Agostinho de-
dc.contributor.otherCAPELLI, Olímpio Murilo-
dc.date.accessioned2026-10-14T20:11:45Z-
dc.date.available2026-10-14T20:11:45Z-
dc.date.issued2019-06-27-
dc.identifier.citationKAVAI, Claudio Kazuo et al. Acionamento de bomba hidráulica com energia fotovoltaica. 2019. Trabalho de Conclusão de Curso (Curso Superior de Tecnologia em Manutenção Industrial) - Faculdade de Tecnologia "Prefeito Hirant Sanazar", Osasco, 2019.pt_BR
dc.identifier.urihttps://ric.cps.sp.gov.br/handle/123456789/49473-
dc.description.abstractAlgumas fontes de energia não renováveis, são utilizadas em grande escala no Brasil, embora num período curto de algumas décadas estas poderão estar esgotadas. Para contornar esse problema uma das tecnologias renováveis que vem sendo cada vez mais utilizada é a energia solar fotovoltaica. Este trabalho apresenta um estudo sobre a viabilidade de acionamento de uma pequena bomba d'agua de corrente contínua de alta pressão por energia fotovoltaico, afim que abastecer a caixa d'água de uma casa ou em locais onde não há rede de energia da concessionaria local, já que o sistema utilizado será off-grid. Para tanta foi realizado vários testes de vazão com alturas manométricas variadas, tempo necessário para a carga e descarga da bateria e tempo total necessário para uma vazão de 100L. A diferença de tempo entre a maior altura -5 metros, e a menor - zero metros, foi de apenas 10 segundos. A variação da corrente ficou na casa do 0,02A. O tempo necessário para a completa carga da bateria em um dia de sol foi de 2h50 minutos e para uma vazão de 100L o tempo transcorrido foi de 33,11minutos. O conjunto mostrou-se capaz de suprir as necessidades do problema proposto, tanto em termos de vazão como de tempo.pt_BR
dc.description.abstractSome non-renewable and highly harmful nature sources are used on a large scale in Brazil, although in a short span of a few decades they may be depleted. To overcome this problem one of the most recent renewable technologies that is being increasingly used is solar photovoltaic energy. This work presents a study on the feasibility of activating a small high pressure direct current water pump for photovoltaic energy, in order to supply the water tank of a house or in places where there is no power grid of the local utility, since the system used will be off-grid. For so much was carried out several tests of flow with varied manometric heights, time necessary for the charge and discharge of the battery and total time necessary for a flow of 100L. The time difference between the highest height - 5 meters, and the lowest - zero meters, was only 10 seconds. The current variation was at 0.02A. The time required to fully charge the battery on a sunny day was 2h50 minutes and for a flow of 100L the elapsed time was 33.11 minutes. The set was able to meet the needs of the proposed problem, both in terms of flow and time.pt_BR
dc.description.sponsorshipCurso Superior de Tecnologia em Manutenção Industrialpt_BR
dc.language.isopt_BRpt_BR
dc.publisher216pt_BR
dc.subjectEnergia solarpt_BR
dc.subject.otherControle e Processos Industriaispt_BR
dc.titleAcionamento de bomba hidráulica com energia fotovoltaicapt_BR
dc.title.alternativeHydraulic pump drive powered by photovoltaic energypt_BR
dc.typeMonografiapt_BR
dcterms.typeNão se aplicapt_BR
Appears in Collections:Trabalhos de Conclusão de Curso



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.