Please use this identifier to cite or link to this item: https://ric.cps.sp.gov.br/handle/123456789/6027
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorSANTOS, Patricia Araújo dos-
dc.contributor.authorSALES, Amanda Regina dos Santos-
dc.contributor.authorGOMES, Ana Paula de Alcantara-
dc.contributor.authorSANTOS, Aryel Fernando Martins dos-
dc.contributor.authorGALVÃO, Tiago Augusto-
dc.contributor.authorCOLIATO, Victória Ribeiro-
dc.date.accessioned2021-10-15T14:24:22Z-
dc.date.available2021-10-15T14:24:22Z-
dc.date.issued2017-
dc.identifier.citationSALES, Amanda Regina dos Santos; GOMES, Ana Paula de Alcantara; SANTOS, Aryel Fernando Martins dos ; GALVÃO, Tiago Augusto; COLIATO, Victória Ribeiro. Construção de um fluorímetro de baixo custo para o estudo da fluorescência em instituição de ensino, 2017. Trabalho de conclusão de curso (Curso Técnico em Química) - Escola Técnica Estadual ETEC Irmã Agostina (Jardim Satélite - São Paulo), São Paulo, 2017.pt_BR
dc.identifier.urihttp://ric.cps.sp.gov.br/handle/123456789/6027-
dc.description.abstractAtualmente, os equipamentos relacionados à espectroscopia de fluorescência molecular estão presentes na área de química analítica em grande escala, possuindo uma construção complexa e consequentemente um alto custo. Tomando-se como base tal informação, procurou-se desenvolver um fluorímetro de baixo custo, utilizando materiais de fácil acesso, com o objetivo de favorecer o contato dos estudantes com essa técnica. Na fabricação da parte externa do equipamento utilizou-se prototipagem rápida por corte a laser de MDF 9 mm. Como fonte de luz empregou-se um LED. Um LDR acoplado a um multímetro foi utilizado como detector e os filtros foram feitos de placas de acrílico coloridas. Nos testes de funcionamento do protótipo o fluoróforo padrão foi a fluoresceína. Nas análises das diluições de fluoresceína foram feitos dois lotes, observou-se que os resultados de ambos não apresentavam reprodutibilidade e nem descrência, como era o previsto. Notou-se que o Led poderia estar interferindo na resposta do LDR e influenciando os resultados. E o filtro acrílico não estava sendo capaz de sozinho evitar que o LDR sobrecarregasse.pt_BR
dc.description.abstractCurrently, equipment related to molecular emission spectroscopy is present in the analytical chemistry on a large-scale, possessing a complex construction and therefore a high cost. Based on such information, it was developed a low-cost fluorimeter using materials of easy access to promoting the contact of the students with this technique. In the manufacture of the outer part of the equipment, rapid prototyping was used by laser cutting 9 mm sheets of MDF. The source of light employed was a LED. A LDR coupled to a multimeter was used as a detector and the filters were made of colored acrylic plates. In the prototype operating tests the standard fluorophore was fluorescein. In the analyzes of the dilutions of fluorescence, they are carried out with the results of both did not present the reproduction and the decoding, as was foreseen. It was noted that the Led could be interfering with the LDR response and influencing the results. And the acrylic filter is not being able to alone prevent the LDR from overloading.-
dc.description.sponsorshipCurso Técnico em Químicapt_BR
dc.language.isopt_BRpt_BR
dc.publisher238pt_BR
dc.subjectCorte a laserpt_BR
dc.subjectConstrução de baixo custopt_BR
dc.subjectQuímica analíticapt_BR
dc.subject.otherProdução Industrialpt_BR
dc.titleConstrução de um fluorímetro de baixo custo para o estudo da fluorescência em instituição de ensinopt_BR
dc.title.alternativeConstruction of a low-cost fluorimeter for the study of fluorescence in an educational institution.pt_BR
dc.typeArtigo científicopt_BR
Appears in Collections:Trabalhos de Conclusão de Curso

Files in This Item:
File Description SizeFormat 
FLUORIMETRO.pdf
  Restricted Access
784.63 kBAdobe PDFView/Open Request a copy


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.