Please use this identifier to cite or link to this item: https://ric.cps.sp.gov.br/handle/123456789/47333
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorALBUQUERQUE, Fernando Antônio Felício-
dc.contributor.authorSANTOS, Lucas Batista dos-
dc.contributor.authorSOUZA, Luiz Enrique Silva-
dc.contributor.authorMARTINS, Marcelo Francisco Josafá Ribeiro-
dc.contributor.authorSILVA, Matheus Ferrante-
dc.contributor.authorNASCIMENTO, Nailah Hirai Koedel do-
dc.contributor.authorSILVA, Thomas Comissário da-
dc.contributor.otherRUFINO, André-
dc.contributor.otherCONDE, Joselito-
dc.date.accessioned2026-08-06T18:46:11Z-
dc.date.available2026-08-06T18:46:11Z-
dc.date.issued2025-12-12-
dc.identifier.urihttps://ric.cps.sp.gov.br/handle/123456789/47333-
dc.description.abstractO projeto tem como objetivo o desenvolvimento de um dispositivo, no formato de pulseira, que, por intermédio de sensores, realiza a coleta e o monitoramento contínuo de parâmetros fisiológicos, tal qual pressão, frequência cardíaca, sono e oxigenação. Em conjunto com um aplicativo, o acompanhamento da saúde acontece por um site que analisa esses dados obtidos pelos sensores, realiza um diagnóstico preditivo de problemas e fornece recomendações personalizadas, especialmente para indivíduos com necessidades de controle contínuo devido a complicações de saúde. Prevê-se que o item terá fácil acessibilidade para que todos com essas complicações possam obtê-lo, principalmente considerando que o design será minimalista, facilitando o custo e minimizando o potencial de incômodo em qualquer posição, o que torna-o mais relevante, considerando que dispositivos com funções semelhantes em seus sistemas são, em geral, caros. É importante ressaltar que este protótipo não produz dados precisamente acurados, uma vez que se utilizam sensores de tamanho reduzido e baixa capacidade – fator, ao qual, justifica o desenvolvimento restrito ao formato de pulseira e a viabilidade do produto. Ademais, como principais sensores destacam-se os de tipo MAX, cujo, são dispositivos que monitoram dados biométricos mediante à meio óptico e elétrico; como exemplos, a emissão e reflexão de LEDs vermelhos e infravermelhos que permitem a mensuração da frequência cardíaca e da oxigenação pelo sensor MAX30102, e a conversão da temperatura em medição analógica e sinal digital para cálculo da temperatura corporal com o sensor MAX30205. Finalmente, embora seja um componente amplamente utilizado em dispositivos eletrônicos concorrentes, também é integrado o acelerômetro ao projeto, cuja função primordial é mensurar a aceleração e a vibração do objeto que está acoplado, viabilizando a obtenção de dados detalhados sobre a movimentação do indivíduo, com o enfoque primário em determinar o padrão de sono do usuário que porta o dispositivopt_BR
dc.description.abstractThe project focuses on developing a bracelet-shaped device designed for the continuous collection and monitoring of physiological parameters, such as blood pressure, heart rate, sleep patterns and oxygen saturation via integrated sensors. In conjunction with a mobile application, health monitoring is performed through a website platform that analyzes the sensor data, provides a predictive diagnosis of potential health issues, and offers personalized recommendations specifically targeted to individuals requiring continuous health monitoring due to existing complications. The device is expected to be easily accessible to anyone with these conditions, particularly considering its minimalist design, which helps to reduce cost and minimizes discomfort when worn, thus increasing its relevance compared to generally expensive competitor systems with similar functions. It’s important to note that this prototype does not produce highly accurate data, as it employs reduced-size, low-capacity sensors – a factor that justifies the development being limited to the wristband format and ensures the product's viability. Furthermore, the main sensors utilized are from the MAX series, which are devices that monitor biometric data using optical and electrical methods; as examples include the MAX30102, which measures heart rate and oxygenation via the emission and reflection of red and infrared LEDs, and the MAX30205, which converts temperature into analog and digital signals for body temperature calculation. Finally, although it’s a widely used component in competing electronic devices, an accelerometer is also integrated, whose primary function is to measure the object's acceleration and vibration, enabling the acquisition of detailed data on the individual's movement, with the primary focus on determining the sleep pattern of the user wearing the device.-
dc.description.sponsorshipCurso Técnico em Eletrônicapt_BR
dc.language.isopt_BRpt_BR
dc.publisher034pt_BR
dc.subjectEletrônicapt_BR
dc.subjectaplicativos móveispt_BR
dc.subjectfrequência cardíacapt_BR
dc.subjectDeterminação da pressão arterialpt_BR
dc.subjectDiagnósticopt_BR
dc.subject.otherControle e Processos Industriaispt_BR
dc.titleSensor Mems automatizado para pulseira de saúdept_BR
dc.typeMonografiapt_BR
dcterms.type-pt_BR
Appears in Collections:Trabalhos de Conclusão de Curso

Files in This Item:
File Description SizeFormat 
eletronica_2025_2_lucassantos_sensormemsautomatizadoparapulseiradesaude.pdf
  Restricted Access
TCC1.92 MBAdobe PDFView/Open Request a copy


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.