dc.identifier.citationALMEIDA, M.R ; IVO, S. V. Avaliação da penetração e diluição no processo MIG/MAG variando o gás de proteção ao Aço SAE 1020. 2023. Monografia (Curso Superior de Tecnologia Mecânica: Processos de Soldagem) - Faculdade de Tecnologia de Pindamonhangaba, Pindamonhangaba, 2023.pt_BR
dc.identifier.urihttps://ric.cps.sp.gov.br/handle/123456789/36433-
dc.description.abstractEste trabalho teve o objetivo de analisar a influência que o gás de proteção exerce na penetração e diluição no aço SAE 1020 utilizando o processo MIG/MAG. Utilizou-se o Laboratório de soldagem da Fatec de Pindamonhangaba, para realizar a soldagem MIG/MAG com arame sólido 1,2 mm ER70S6, variando o gás de proteção, Argônio Puro e Argônio 80% e CO2 20%. Foi utilizado a Chapa de aço SAE 1020, com as dimensões: 100X200x 6,24mm. Utilizou-se a máquina de solda MIG/MAG automática, marca Lincoln Electric modelo Power Wave S350,com os seguintes parâmentos de Soldagem: 30 V, 198 A, Velocidade do arame 8 m/mm, Velocidade de soldagem 30 cm/min, Posição 1G, Vazão do Gás Argônio 15L/min, Distância da tocha 10 mm, Ângulo da tocha 20°. A proteção de gás Argônio Puro, apresentou a penetração cerca de 15% menor quando comparado com a penetração da proteção de gás Argônio 80% CO2 20%. A diluição com o gás de proteção Argônio Puro foi de 33% e ja a proteção com o gás argônio 80% CO2 20% foi de 46%. Conclui- se que o a Variação de gás Inerte (Argônio Puro) e mistura de gás Ativo com Inerte (Argônio 80% CO2 20%) no processo de soldagem MIG/MAG, não ocorreu mudança nas microestruturas das regiões da solda e ZTA. As mesmas estruturas foram observadas em todas as amostras analisadas. A penetração houve um aumento expressivo e já na diluição apresentou um aumento superior ao encontrado na literatura para este processo.pt_BR
dc.description.abstractThis work aimed to analyze the influence that the shielding gas exerts on penetration and dilution in SAE 1020 steel using the MIG/MAG process. The Welding Laboratory at Fatec in Pindamonhangaba was used to carry out the MIG/MAG welding with solid wire 1.2 mm ER70S6, varying the shielding gas, Pure Argon and Argon 80% and CO2 20%. Steel sheet SAE 1020 was used, with dimensions: 100X200x 6.24mm. An automatic MIG/MAG welding machine, Lincoln Electric model Power Wave S350, was used, with the following welding parameters: 30 V, 198 A, Wire speed 8 m/mm, Welding speed 30 cm/min, Position 1G, Argon Gas Flow 15L/min, Torch distance 10 mm, Torch angle 20°. The Pure Argon gas protection showed a penetration of about 15% less when compared to the penetration of the Argon 80% CO2 20% gas protection. The dilution with Pure Argon gas protection was 33% and the protection with 80% CO2 20% argon gas was 46%. It is concluded that the Variation of Inert gas (Pure Argon) and mixture of Active and Inert gas (Argon 80% CO2 20%) in the MIG/MAG welding process, there was no change in the microstructures of the weld regions and HAZ. The same structures were observed in all analyzed samples. There was a significant increase in penetration and in the dilution it showed a higher increase than that found in the literature for thispt_BR
dc.description.sponsorshipCurso Superior de Tecnologia em Mecânica: Processos de Soldagempt_BR
dc.language.isopt_BRpt_BR
dc.publisher133pt_BR
dc.subjectAço baixo carbonopt_BR
dc.subjectSoldagem a gáspt_BR
dc.subjectSoldagem migpt_BR
dc.subjectSoldagempt_BR
dc.subject.otherControle e Processos Industriaispt_BR
dc.titleAvaliação da penetração e diluição no processo MIG/MAG variando o gás de proteção ao aço SAE 1020pt_BR
dc.title.alternativeEvaluation of penetration and dilution in the MIG/MAG process changing the shielding gas for SAE 1020 steelpt_BR
dc.typeMonografiapt_BR
dcterms.type-pt_BR
Appears in Collections:Trabalhos de conclusão de curso



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.