dc.identifier.citationMÁS, Flávio Eduardo; CARVALHO JÚNIOR, Vanderlei Antônio Bueno de. Avaliação de corrosão em aços dissimilares A36 e inox 304 soldados pelo processo "SMAW" usando três diferentes eletrodos. 2018. Trabalho de Graduação (Curso Superior de Tecnologia em Mecânica: Processos de Soldagem) - Faculdade de Tecnologia de Sertãozinho "Dep. Waldyr Alceu Trigo", Sertãozinho, 2018.pt_BR
dc.identifier.urihttps://ric.cps.sp.gov.br/handle/123456789/21071-
dc.description.abstractEste trabalho teve como objetivo realizar um estudo comparativo sobre a corrosão de uma junta soldada com dois materiais dissimilares: o aço baixa liga SAE A36 e o aço inox AISI 304, com três diferentes tipos de eletrodos revestidos, sendo eles: E 308L, E 309L, E7018. Realizou-se ensaios de corrosão por imersão em solução de ácido clorídrico 5% com fluoreto de sódio 3% utilizando-se duas amostras de cada conjunto soldado com os respectivos metais de adição, sendo um corpo de prova composto pelo aço inox somente com a solda e a outra amostra, composta do aço inox, a solda e o aço carbono. O tempo total do ensaio foi de 192 horas sendo que a cada 24 horas, fez-se a retirada, a lavagem e a pesagem, para análise das perdas de massa além da visualização da superfície através do exame metalográfico. Observou-se com os dados coletados, que o eletrodo E309L demonstrou o melhor resultado, pois apresentou menor perda de massa e menor intensidade de corrosão.pt_BR
dc.description.abstractThe objective of this work was to conduct a comparative study on the corrosion of a joint welded with two dissimilar materials: the low alloy steel SAE A36 and the stainless steel AISI 304, with three different types of coated electrodes: E 308, E309, and E7018. Corrosion tests were carried out by immersion in 5% of hydrochloric acid solution with 3% sodium fluoride using two samples of each set welded with the respectie addition metals, being a test composed of stainless steel only with the weld and the other sample, composed of stainless steel, welding, and carbon steel. The total time of examination was 192 hours and a retreat, a wash and a weighing were done every 24 hours, to analyze the mass losses in addition to the surface view through the metallographic test. It was observed with the collected data, that the E309 electrode presented the best result, as it presented lower mass loss and lower corrosion intensity.-
dc.description.sponsorshipCurso Superior de Tecnologia em Mecânica: Processos de Soldagempt_BR
dc.language.isopt_BRpt_BR
dc.publisher176pt_BR
dc.subjectMecânicapt_BR
dc.subjectAço carbonopt_BR
dc.subjectCorrosãopt_BR
dc.subjectAço inoxidávelpt_BR
dc.subject.otherControle e Processos Industriaispt_BR
dc.titleAvaliação de corrosão em aços dissimilares A36 e inox 304 soldados pelo processo "SMAW" usando três diferentes eletrodospt_BR
dc.title.alternativeCorrosion assessment in dissimilar A36 and 304 stainless steels welded by the "SMAW" process using three different electrodespt_BR