dc.identifier.citationCARVALHO, Gilberto Alves de. Limpeza e desinfecção externa das máquinas de hemodiálise. Trabalho de conclusão de curso (Curso Superior de Tecnologia em Sistemas Biomédicos) - Faculdade de Tecnologia FATEC Bauru, Bauru, 2019pt_BR
dc.identifier.urihttp://ric.cps.sp.gov.br/handle/123456789/10007-
dc.description.abstractEste trabalho apresenta uma revisão sobre as maquinas de hemodiálise, discutindo principalmente os processos de desinfecção e manutenção. O custo de uma sessão de hemodiálise é alto e por isso a manutenção do equipamento de hemodiálise se faz necessário. A manutenção do equipamento envolve tanto a reparação da maquina quanto os processos de desinfecção que devem ser realizados após a sessão de hemodiálise. A desinfecção da máquina de hemodiálise pode ser dividida em dois diferentes processos: a desinfecção externa (álcool 70 % ou Glucoprotamina (Incidin ®)) e a desinfecção interna (ácido paracético). O uso adequado do equipamento permite uma longa duração da máquina, além de garantir a segurança do paciente. Além disso, é apresentado outros parâmetros importantes quando se fala de uma sessão de hemodiálise, tais como o reuso do dialisador e a qualidade da água que será utilizada. Conclui-se que na desinfecção da máquina de hemodiálise o mais importante é o dialisador, que passa pelo processo químico, principalmente com ácido paracético evitando que o paciente tenha uma contaminação ao reutilizar o filtro.pt_BR
dc.description.abstractThis paper presents a review of hemodialysis machines, mainly discussing disinfection and maintenance processes. The cost of a hemodialysis session is high and therefore maintenance of hemodialysis equipment is required. Equipment maintenance involves both machine repair and disinfection processes that must be performed after the hemodialysis session. The disinfection of the hemodialysis machine can be divided into two different processes: an external disinfection (alcohol 70% or Glucoprotamina (Incidin ®)) and an internal disinfection (paracetic acid). Proper use of the equipment allows long machine life and patient safety. In addition, other important parameters are presented when talking about a hemodialysis session, such as reuse of the dialyzer and the water quality that will be used. It is concluded that in the disinfection of the hemodialysis machine the most important is the dialyzer, which goes through the chemical process, mainly with paracetic acid, preventing the patient from having a contamination when reusing the filter.pt_BR
dc.description.sponsorshipCurso Superior de Tecnologia em Sistemas Biomédicospt_BR
dc.language.isopt_BRpt_BR
dc.publisher196pt_BR
dc.subjectHemodiálisept_BR
dc.subjectServiço hospitalar de limpezapt_BR
dc.subject.otherAmbiente e Saúdept_BR
dc.titleLimpeza e desinfecção externa das máquinas de hemodiálisept_BR
dc.title.alternativeCleaning and external disdinfection of hemodialysis machinespt_BR
dc.typeArtigo científicopt_BR
Appears in Collections:Trabalhos de Conclusão de Curso